Last Modified: 11-29-2007 |
1.6 A |
|
Service Category: Engine/Hybrid System |
Section: Engine Control |
|
Model Year: 2008 |
Model: Sequoia |
Doc ID: RM00000329100BX |
|
Title: 2UZ-FE ENGINE CONTROL: ECM: INSTALLATION (2008 Sequoia) |
INSTALLATION
1. INSTALL GASKET
(a) Clean the ECM seal's surface with non-residue solvent.
(b) Attach a new gasket to the ECM.
2. INSTALL ECM
|
(a) Install the ECM with the 4 bolts.
Torque: 8.0 N·m (82 kgf·cm, 71 in·lbf)
NOTICE:
-
Make sure the gasket is not folded or caught on any area on the surrounding part.
-
Make sure there is no foreign matter caught between the gasket and surrounding part.
-
Do not damage the gasket.
|
|
(b) Connect the 2 ECM connectors and push each lock lever down to lock the 2 ECM connectors.
NOTICE:
-
Make sure that the lock lever is raised 90° before connecting the ECM connectors. Failure to do this may cause the lock lever and terminals to break.
-
Do not twist the wire harness when connecting the ECM connectors.
|
|
(c) Connect the wire harness clamp.
|
3. INSTALL CONNECTOR HOLDER BLOCK
|
(a) Install the connector holder block with the 3 bolts.
Torque: 7.3 N·m (74 kgf·cm, 65 in·lbf)
|
4. INSTALL AIR CLEANER ASSEMBLY
(a) Install the air cleaner assembly with the 2 bolts.
Torque: 5.0 N·m (51 kgf·cm, 44 in·lbf)
(b) Connect the mass air flow meter connector and clamp.
5. INSTALL AIR CLEANER HOSE ASSEMBLY
6. INSTALL THROTTLE BODY COVER SUB-ASSEMBLY
7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
Some systems need to be initialized after the cable is reconnected
.
8. PERFORM INITIALIZATION
(a) Perform initialization procedures
.
|